SurvivingUtopia

What size power station do you need for a hurricane?

Short answer: a fridge, a freezer, a fan and Wi-Fi use about 3–4 kWh a day. A 2–3 kWh power station covers roughly one day. To last a week you need enough solar to refill it daily (often 800 W or more) or a generator to top it up. Here's how to work out your own number.

Step 1: Count watt-hours, not watts

A power station's capacity is in watt-hours (Wh). That's watts multiplied by hours. A 50 W box fan running 10 hours uses 500 Wh. A phone charge is only about 15 Wh. The big daily users in a typical outage are the ones that run all day: the refrigerator, the chest freezer, and your modem and router.

Step 2: Use average draw for anything with a compressor

The sticker on a fridge might say 150 W running and 1,200 W at startup. But the compressor cycles on and off, so a modern fridge averages roughly 40–80 W across a day, or about 1–2 kWh. If you size for 150 W around the clock, you'll buy twice the battery you need. Better yet, plug the fridge into an energy-monitoring smart plug for a few days before storm season and use the real number.

Step 3: Size the inverter for the surge

Capacity and output are separate specs. The inverter has to handle everything running at once plus the startup spike of the largest motor. A fridge that kicks on while a fan and laptop are running can briefly ask for 1,300 W or more. A 1,800–2,000 W inverter covers most fridge-and-fans setups. A window AC unit pushes you higher.

Step 4: Decide how much solar does the heavy lifting

In Florida, a fair planning number is 4–5 peak sun hours a day. Real output is lower than the panel rating because of heat, angle and clouds, so derate by about 25%. A 400 W panel set realistically gives 1.2–1.5 kWh on a decent day. That's enough to refill a fridge on its own, but not a fridge plus a freezer and fans. The battery then only needs to bridge nights and a cloudy day or two, not the whole outage.

Step 5: Pick battery chemistry

LiFePO4 (lithium iron phosphate) stations cost more up front but last thousands of cycles, tolerate heat better, and let you use about 90% of the rated capacity. For gear that sits ready for years and then works hard for two weeks, that's worth paying for.

Typical sizes

Rather than guess, put your actual devices into the calculator. It does all five steps at once.

Run your own numbers: open the free OutageReady calculator →